MIO Laborbefund
Version 1.0.0-update - ci-build

ValueSet: Messergebnis Qualitativ SNOMED CT®

Official URL: https://fhir.kbv.de/ValueSet/KBV_VS_MIO_LAB_Observation_Laboratory_Study_Value_SNOMED_CT Version: 1.0.0-update
Draft as of 2026-06-19 Computable Name: KBV_VS_MIO_LAB_Observation_Laboratory_Study_Value_SNOMED_CT

Copyright/Legal: Im folgenden Profil können Codes aus den Codesystemen Snomed, Loinc oder Ucum enthalten sein, die dem folgenden Urheberrecht unterliegen: This material includes SNOMED Clinical Terms® (SNOMED CT®) which is used by permission of SNOMED International. All rights reserved. SNOMED CT®, was originally created by The College of American Pathologists. SNOMED and SNOMED CT are registered trademarks of SNOMED International. Implementers of these artefacts must have the appropriate SNOMED CT Affiliate license. This material contains content from LOINC (http://loinc.org). LOINC is copyright © 1995-2020, Regenstrief Institute, Inc. and the Logical Observation Identifiers Names and Codes (LOINC) Committee and is available at no cost under the license at http://loinc.org/license. LOINC® is a registered United States trademark of Regenstrief Institute, Inc. This product includes all or a portion of the UCUM table, UCUM codes, and UCUM definitions or is derived from it, subject to a license from Regenstrief Institute, Inc. and The UCUM Organization. Your use of the UCUM table, UCUM codes, UCUM definitions also is subject to this license, a copy of which is available at ​http://unitsofmeasure.org. The current complete UCUM table, UCUM Specification are available for download at http://unitsofmeasure.org. The UCUM table and UCUM codes are copyright © 1995-2009, Regenstrief Institute, Inc. and the Unified Codes for Units of Measures (UCUM) Organization. All rights reserved. THE UCUM TABLE (IN ALL FORMATS), UCUM DEFINITIONS, AND SPECIFICATION ARE PROVIDED “AS IS.” ANY EXPRESS OR IMPLIED WARRANTIES ARE DISCLAIMED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Dieses Valueset enthält die Codes zur Beschreibung von Messergebnis Qualitativ SNOMED CT®.

References

Logical Definition (CLD)

 

Expansion

Expansion from tx.mio42.de based on SNOMED CT German Edition edition 15-Nov 2025

This value set contains 38 concepts

SystemCodeDisplay (de)Other Display (null)en, deDisplay (English)Other Display (Deutsch)JSONXML
http://snomed.info/sct  260347006+ aus ++++ vorhanden+Present + out of ++++ (qualifier value)+ (qualifier value)+ aus ++++ vorhanden
http://snomed.info/sct  260348001++ aus ++++ vorhanden++Present ++ out of ++++ (qualifier value)++ (qualifier value)++ aus ++++ vorhanden
http://snomed.info/sct  260349009+++ aus ++++ vorhanden+++Present +++ out of ++++ (qualifier value)+++ (qualifier value)+++ aus ++++ vorhanden
http://snomed.info/sct  260350009++++ aus ++++ vorhanden++++Present ++++ out of ++++ (qualifier value)++++ (qualifier value)++++ aus ++++ vorhanden
http://snomed.info/sct  441614007+ aus +++ vorhandenPresent one plus out of three plusPresent + out of +++Present one plus out of three plus (qualifier value)+ aus +++ vorhanden
http://snomed.info/sct  441517005++ aus +++ vorhandenPresent two plus out of three plusPresent ++ out of +++Present two plus out of three plus (qualifier value)++ aus +++ vorhanden
http://snomed.info/sct  441521003+++ aus +++ vorhandenPresent three plus out of three plusPresent three plus out of three plusPresent +++ out of ++++++ aus +++ vorhanden
http://snomed.info/sct  260373001NachgewiesenDetectedDetectedDetected (qualifier value)Entdeckt
http://snomed.info/sct  260385009NegativNegativeNegativeNegative (qualifier value)Negativ
http://snomed.info/sct  260392004Nicht-durchgängigNon-patentNon-patentNon-patent (qualifier value)Nicht-durchgängig
http://snomed.info/sct  260415000Nicht nachgewiesenNot detectedNot foundNot detected (qualifier value)Nicht nachgewiesen
http://snomed.info/sct  52101004VorhandenPresentPresent (qualifier value)Presence ofVorhanden
http://snomed.info/sct  10828004PositivPositivePositivePositive (qualifier value)Positiv
http://snomed.info/sct  2667000AbwesendAbsentAbsentAbsent (qualifier value)Abwesend
http://snomed.info/sct  895231008Nicht nachgewiesen in PoolprobeNot detected in pooled specimenNot detected in pooled specimen (qualifier value)Not detected in pooled specimenNicht nachgewiesen in Poolprobe
http://snomed.info/sct  720735008Vermutlich positivPresumptive positivePresumed positivePresumptive positiveVermutlich positiv
http://snomed.info/sct  373067005NeinNoNo (qualifier value)NoNein
http://snomed.info/sct  373066001JaYesYes (qualifier value)YesJa
http://snomed.info/sct  264887000Nicht isoliertNot isolatedNot isolatedNot isolated (qualifier value)Nicht isoliert
http://snomed.info/sct  264868006Kein WachstumNo growthNo growthNo growth (qualifier value)Kein Wachstum
http://snomed.info/sct  260413007KeinNoneNoneNone (qualifier value)Kein
http://snomed.info/sct  260408008Schwach positivWeakly positiveWeakly positiveWeakly positive (qualifier value)Schwach positiv
http://snomed.info/sct  260405006SpurTraceTraceTrace (qualifier value)Spur
http://snomed.info/sct  260389003Keine ReaktionNo reactionNo reactionNo reaction (qualifier value)Keine Reaktion
http://snomed.info/sct  46651001IsoliertIsolatedIsolatedIsolated (qualifier value)Isoliert
http://snomed.info/sct  419984006Nicht auswertbarInconclusiveInconclusive (qualifier value)InconclusiveNicht auswertbar
http://snomed.info/sct  42425007ZweideutigEquivocalEquivocalEquivocal (qualifier value)Zweideutig
http://snomed.info/sct  82334004UneindeutigIndeterminateIndeterminateNot exactly known or degree or value not exactly establishedUnbestimmt
http://snomed.info/sct  62482003NiedrigLowLowLow (qualifier value)Niedrig
http://snomed.info/sct  11214006ReaktivReactiveReactiveReactive (qualifier value)Reaktiv
http://snomed.info/sct  131194007Nicht-reaktivNon-ReactiveNon-ReactiveNon-Reactive (qualifier value)Nicht-reaktiv
http://snomed.info/sct  280416009Unbestimmtes ErgebnisIndeterminate resultIndeterminate resultIndeterminate result (qualifier value)Unbestimmtes Ergebnis
http://snomed.info/sct  75540009HochHighHighHigh (qualifier value)Erhöht
http://snomed.info/sct  455371000124106Ungültiges ErgebnisInvalid resultInvalid result (qualifier value)Invalid resultUngültiges Ergebnis
http://snomed.info/sct  89292003SeltenRareRareRare (qualifier value)Selten
http://snomed.info/sct  262008008Nicht durchgeführtNot performedNot performedNot performed (qualifier value)Nicht durchgeführt
http://snomed.info/sct  17621005NormalNormalNormalNormal (qualifier value)Normal
http://snomed.info/sct  277025001ErwiesenProvenProvenProven (qualifier value)Erwiesen

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code